INDUSTRIAL
SERIAL RS232 / RS485 /
RS422
TO FIBER OPTIC CONVERTER
SINGLE MODE (SM)
30 Day Money Back / 5 Year Replacement
Guarantee
"Simple and Hassle-Free Operation
Completely Auto-Sensing and Self-Adjusting
No Manual Settings Necessary At All"
|
ST CONNECTOR
TYPE |
SC CONNECTOR
TYPE |
SerialComm Model: SER-FIBER-SM
Download Specs.
SER-FIBER-SM.PDF
FREQUENTLY
ASKED QUESTIONS
IN STOCK
ST MODEL - SER-FIBER-SM-ST -
$165.95
SC MODEL - SER-FIBER-SM-SC -
$165.95
 |
|
DESCRIPTION
The SerialComm SER-FIBER-SM is a high quality
industrial-grade bi-directional externally powered RS-232 / RS-485 /
RS-422 to single mode (SM) fiber optic converter (fiber optic modem)
enclosed in a heavy-duty steel housing. Besides the capability of
long distance data transmission, fiber lines are inherently
resistant to EMI/RFI and transient surges including lightning;
therefore, they are ideal for data communications near heavy
electrical equipment and other electrical or atmospheric
interference conditions. The single mode fiber optic converter can
extend the RS232 / RS485 / RS422 signal distance to up to 12.4 miles
(20 km) using SM fiber optic cable. The RS232, RS485, and RS422 can
be connected in any configuration; for instance RS232 can be
converted to RS485 or RS422 via fiber. The unit supports serial data
rates up to 460kbps and features auto-sensing data turnaround and
therefore requires no flow control or any software drivers, The
converter has no DIP switches or jumpers making it Plug-and-Play.
The 232-FIBER-SM has a terminal block connector for easy
installation and either ST type or SC type connectors for the fiber
optic links which needs to be specified. The media converter is
wall, panel, or DIN rail mountable. Free optional DIN rail mounts
are available at checkout for this converter. An external 9V-36V /
100V-240V power adapter is included in package. This product is
backed by our 30 day money back guarantee and 5 year warranty.
FEATURES
- Plug-and-Play (hot-pluggable)
- Easily mounted on a DIN-rail, panel wall or piggyback
- Transmission speeds of up to 460kbps
- Fiber optic range of up to 12.4 miles (20 km)
- Available with ST or SC type connectors
- Half or full duplex bi-directional transmission
- Free optional DIN rail mounts
- RS-232/RS-485/RS-422 can be mixed or matched
- Data direction auto-turnaround - no flow control is
necessary
- Built-in surge, static and over-current protection
- LED indicators for power and data
- No software drivers are necessary
- Power required: 9V - 36VDC
- 5 year manufacturer’s warranty
- RoHS, CE and FCC certified
|
SPECIFICATIONS
|
STANDARDS: |
EIA/TIA RS-232C, RS-485 and RS-422 Standards |
|
MODEL NUMBERS: |
SER-FIBER-SM-ST - ST Connector Version
SER-FIBER-SM-SC - SC Connector Version |
|
BAUD RATES: |
From 300 Baud To 460,000 Baud |
| CONNECTOR
TYPES: |
DC Input: 2-way Terminal Block, Serial Side:
8 Position Terminal Block and
Fiber Side: either 2 X ST or 2 X SC
Connectors Depending on Selected Model |
|
DISTANCE: |
RS-232 Side: 16 ft (5m), RS-485/RS-422
Side: 4000 ft (1.2km) and Single Mode Side:
12.4 miles (20km) |
|
POWER SOURCE: |
9VDC to 36VDC |
|
DC/AC POWER ADAPTER: |
Included 9VDC/(100-240VAC 50/60hz US
Type A Plug) 500 mA |
|
CURRENT CONSUMPTION: |
4 Watts |
|
STATIC PROTECTION: |
15KV Electric Static Discharge (ESD) Protection |
|
SURGE PROTECTION: |
600W/Sec Surge Protection |
|
FIBER OPTIC CABLING: |
Compatible with Single Mode 8.3/125um,
8.7/125um, 9/125um or 10/125um Fiber Optic Cable |
|
WAVELENGTH: |
1310nm |
| HOUSING: |
Heavy Duty Steel Housing |
| DIN RAIL: |
Free Optional DIN Rail Mounts |
|
WEIGHT: |
With ST
Connector: 8.87oz (251.4 grams)
With SC
Connector: 8.73oz (254.3 grams) |
|
DIMENSIONS: |
With ST
Connector: 4.96 X 3.58 X
0.87
in (126.0 X 91.0 X 22.0 mm)
With SC
Connector:
4.65 X 3.58 X 0.87 in (118.0 X 91.0 X 22.0 mm) |
|
OPERATING TEMP.: |
-40ºF to 185ºF (-40ºC to
85ºC) |
|
OPERATING HUMIDITY: |
5% To 95% - No Condensation |
|
PRODUCT SAFETY: |
CE, FCC and RoHS Conformance
Certified |
|
RELIABILITY: |
Low Failure Rate - 99+% Reliability
Since Inception |
|
WARRANTY: |
5 Year Replacement Warranty |
|
POWER AND SERIAL CONNECTORS

LED INDICATIONS
|
PWR |
Power Indicator |
ON: Power
On - OFF: Power Off |
|
RX |
Data Receive Indicator |
ON: When
Power is Connected - OFF: When Fiber is
Connected - FLASHING: When Data is
Received |
|
TX |
Data Transmit Indicator |
FLASHING: When Data is Transmitted |
FLEXIBLE SERIAL CONVERSION
This serial converter is very versatile.
Not only can you extend RS-232, RS-485 or RS-422 data but convert from one
serial protocol to another. For instance on one end of the fiber optic
you can connect RS-232 and the other RS-485 or RS-485 to RS-44 or any other
combination.
|
APPLICATIONS

FIGURE 1: EXTENDING THE RS232 DATA
DISTANCE

FIGURE 2: EXTENDING THE RS485 DATA DISTANCE

FIGURE 3: EXTENDING THE RS422 DATA DISTANCE
TROUBLESHOOTING INSTRUCTIONS
| |
Using one SER-FIBER-SM unit:
Perform a loop back test on one unit:
Plug the power connector to the
converter. Both the PWR light
and RX light should be on.
Connect the fiber optic in to
fiber optic out. Only the PWR
light should be lit.
Connect the RS-232C port to the PC RS-232 port.
Running a hyper terminal program on the PC, send ASCII characters to the
SER-FIBER-SM converter from one PC port, and check that the characters are received at the same PC port. This tests that the transmit and receive functions of the
SER-FIBER-SM unit is working properly.
When data is transmitting to the
converter the TX light should blink
and when the converter is receiving
data the RX light should blink.
Using two SER-FIBER-SM units:
Check that all connections comply with the connection diagrams.
Perform a loop back test on two units:
Plug the power connector to the
converter. Both the PWR light
and RX light should be on both
units.
Connect the fiber optic in of
one converter and fiber optic out to
the other converter.
Connect the fiber optic out of
one converter and fiber optic in of
the other converter.
Only the PWR light should be lit
on both converters.
Connect the two RS-232C ports to two PC RS-232 ports.
Running hyper terminal programs on both PCs, send ASCII characters to the
SER-FIBER-SM converter from one PC port, and check that the characters are received at the 2nd PC port. Repeat the test in the opposite direction. This tests that the transmit and receive functions of both
SER-FIBER-SM units are working properly.
When data is transmitting to the
converter the TX light should blink
and when the converter is receiving
data the RX light should blink.
Download FREE FULL VERSION AccessPort Advanced
Serial Monitor, Simulation and Data Analysis Software Tool. This
software tool is great for testing converters. Supports Windows 98/XP/VISTA/WIN
7. DOWNLOAD SOFTWARE |
|
DIMENSIONS
 |
|